Compressor contactor replacement in Forney,TxCompressor contactor replacement in Forney,Tx
🔥 Burnt Contactor? No Problem! 🔧
We were called out to a home in Forney, TX today where the A/C had completely stopped working. After a quick diagnosis, we found the compressor contactor was burnt and failing to send power to the unit. ⚡️
This kind of failure can lead to major cooling issues — especially with Texas heat bearing down! We replaced the contactor, tested the system, and got everything running smoothly again. ❄️✅
If your system isn’t keeping up or making strange noises, don’t wait — a small issue can turn into a big one fast.
📍 Serving Forney and surrounding areas
📞 Call us anytime for fast, honest HVAC service!
#HVAC #ForneyTX #ACRepair #SummerReady #LocalService #BeforeAndAfter
-
Rusty overflow drain pan in dallas txRusty overflow drain pan in dallas tx
Customer experienced water on ceiling and floor. We found the primary line clogged and the overflow pan rusted through.
-
Washed condenser coils lennox AC- Garland,TxWashed condenser coils lennox AC- Garland,Tx
AC Tune-Up & Coil Cleaning – Lennox Unit | Garland, TX
Performed a comprehensive air conditioning tune-up on a Lennox unit in Garland, TX. The system was experiencing reduced cooling efficiency due to severely plugged condenser coils. Our technician thoroughly cleaned the condenser coils using a specialized coil cleaner and low-pressure water rinse to restore proper airflow and heat transfer.
Additional tune-up steps included checking refrigerant levels, inspecting electrical components, tightening connections, and ensuring the thermostat was calibrated correctly. The unit is now running efficiently and is ready to handle the Texas summer heat.
-
Condenser coil washing. Dallas , TxCondenser coil washing. Dallas , Tx
🛠️ Clogged Condenser Coil? We’ve Got It Covered! ☀️
📍 Dallas, TX
Today, we diagnosed a cooling issue that turned out to be a clogged condenser coil — a common problem that can seriously impact your system’s efficiency, especially in this Texas heat!
To clean it properly, we removed the top of the unit to access the coil from the inside out. This method ensures a thorough wash, preventing debris buildup and restoring optimal airflow. 💨
Remember: Dirty coils force your system to work harder, leading to higher energy bills and potential breakdowns. If your AC isn’t keeping up, it might be time for a coil check.
📅 Schedule your maintenance today and keep cool, Dallas!
#HVACDallas #CondenserCleaning #PreventiveMaintenance #DallasTXCooling #StayCoolTexas
-
Drain line piped incorrectly- Rockwall,TxDrain line piped incorrectly- Rockwall,Tx
Diagnosed water damage to ceiling. Found the drain line not properly level and piped in correctly.
-
Dual capacitor replacement carrier unit. Allen,TxDual capacitor replacement carrier unit. Allen,Tx
Dispatched to commercial site in Allen, TX to address HVAC performance issues on a Carrier rooftop unit. Upon inspection, found the dual run capacitor (serving both compressor and fan motor) was weak and out of manufacturer’s spec, causing intermittent operation and reduced cooling performance. Replaced faulty dual capacitor with OEM-rated component. Verified proper microfarad rating and secure electrical connections. Tested unit operation after replacement—compressor and condenser fan motor both started and ran correctly. System pressures and amp draws returned to normal range. Rooftop unit is now operating as designed.
-
Clogged condensation drain line. Dallas,TxClogged condensation drain line. Dallas,Tx
We unclogged the condensation line by using high-pressure nitrogen to safely and effectively clear the blockage. After identifying the clog in the drain line under the sink, we connected a nitrogen tank to the line and released a controlled burst of nitrogen gas. The high-pressure force quickly dislodged the buildup of debris, algae, and gunk that was causing the obstruction. Once the line was cleared, we flushed it to ensure proper drainage and confirmed that water was flowing freely again. Using nitrogen is a clean, efficient, and non-damaging method to clear HVAC drain lines without the use of harsh chemicals.
-
Evaporator coil replacement. Goodman. Dallas,TxEvaporator coil replacement. Goodman. Dallas,Tx
We replaced a leaking evaporator coil and saved customer thousands of dollars in not having to to replace whole system.
-
Evaporator coil replacement goodman Dallas,TxEvaporator coil replacement goodman Dallas,Tx
-
Compressor Contactor Replaced Dallas,TxCompressor Contactor Replaced Dallas,Tx
Do not let the ants eat up your compressor contactor. Best you can do is spray a barrier around your outside unit to avoid costly repairs. If you are currently using a pest control, ask them to spray around the outdoor unit!!
-
Air conditioning repair grand prairieAir conditioning repair grand prairie
Technician arrived on site in Grand Prairie, TX to inspect reported issues with the HVAC system. Upon evaluation, found several burnt compressor contactors in the system, indicating overheating and electrical arcing. The damaged contactors were beyond repair and posed a risk of system failure.
All affected contactors were removed and replaced with new, manufacturer-approved components. After replacement, system was powered on and tested for proper operation. Compressor now engages correctly, and all electrical connections are secure. System is functioning as expected at the time of departure.
-
Air conditioning Repair. Dallas,TxAir conditioning Repair. Dallas,Tx
The condenser coil has been thoroughly cleaned, restoring proper airflow and improving system efficiency. This helps ensure better cooling performance and extends the life of the equipment.
-
Air conditioning Repair. Dallas,TxAir conditioning Repair. Dallas,Tx
Heavy dirt and debris buildup inside the condenser coil was restricting airflow and reducing system efficiency. This kind of blockage can lead to poor cooling performance and increased energy usage.
-
Air conditioning Repair. Dallas,TxAir conditioning Repair. Dallas,Tx
Our team responded to a no cooling call and identified two main issues. We replaced a failed dual capacitor and thoroughly cleaned a plugged condenser coil to restore proper system operation. The cooling system is now running efficiently.
-
Evaporator coil replacementEvaporator coil replacement
Here’s a professional and clear description you can use for an evaporator coil replacement on a Carrier unit due to a leak:
Evaporator Coil Replacement – Carrier System
Performed a full evaporator coil replacement on a Carrier HVAC system due to a confirmed refrigerant leak. This unit was sitting against the roof eaves and against the spray styrofoam making it difficult to work on the back side. We stuck with it and was able to restore cooling.
-
Air Conditioning Repair-heat pumpAir Conditioning Repair-heat pump
Today, we replaced the failed blower motor and blower wheel on a Goodman heat pump system. Upon arrival, the system was inspected and diagnosed with a faulty blower motor causing poor airflow and system inefficiency. The blower wheel was also found to be worn and imbalanced.
-
Thermostat replacementThermostat replacement
We removed a older thermostat and replaced with a new one. Customer wanted to be able to contol the thermostat thru the app.
-
Burnt bulbs in ultravioletBurnt bulbs in ultraviolet
During a inspection. We found the bulbs burnt out on the ultraviolet light.
-
Dirty circuit board in gas furnaceDirty circuit board in gas furnace
We performed a annual maintenance, during our inspection, we found the circuit board covered in dust. We blew out the control section with panel with nitrogen. Having a dusty control board will short out the diodes and resistors.
-
Air conditioning Repair. Dallas,TxAir conditioning Repair. Dallas,Tx
Responded to a no cooling call. Found dual capacitor reading 0 MFD on compressor side. Replaced dual capacitor. Restarted cooling.
-
Air conditioning Repair. Dallas,TxAir conditioning Repair. Dallas,Tx
After pictures of the clean condenser coils on lennox condenser unit.
-
Air conditioning repair, Dallas, TxAir conditioning repair, Dallas, Tx
Picture of washing the condenser coils on Lennox unit. Will post after pictures of clean coil
-
Air conditioning repair, Dallas,TxAir conditioning repair, Dallas,Tx
Responded to a no cooling call. After diagnosis we took off the panels to this lennox unit and discovered the condenser coils were extremely dirty. Will post during pics of coil washing
-
Leaking evaporator coil- Richardson,TxLeaking evaporator coil- Richardson,Tx
No cool call. Customer experience outdoor unit short cycling. After diagnostic, found unit low on freon which the low pressure switches switch is causing the short cycling. We performed a leak search and found the coil leaking. We added freon for now until we replace the coil.
-
Air Repair- Frisco,TxAir Repair- Frisco,Tx
Responded to a no cooling call in Frisco. After performing annual maintenance on both systems. We found dual capacitor blown for downstairs unit. We were able to repair the unit and te store the cooling.
-
Cleaned condenser coil - lennox condenserCleaned condenser coil - lennox condenser
Upon arrival, the customer reported that the system was not cooling. Performed a full diagnostic on the Lennox air conditioning unit. Found the system running but not providing adequate cooling. Inspected electrical components, refrigerant levels, and airflow. Discovered the outdoor condenser coil was significantly dirty, restricting heat exchange and causing poor system performance.
Shut off power to the unit and performed a thorough cleaning of the condenser coil using coil cleaner and water. Removed all debris and buildup from the fins to restore proper airflow. After cleaning, rechecked system operation. Verified compressor and condenser fan motor were operating within normal parameters. Monitored refrigerant pressures, which stabilized after cleaning, indicating
-
Washed condenser coil- Garland TxWashed condenser coil- Garland Tx
Upon arrival, the customer reported that the system was not cooling. Performed a full diagnostic on the Lennox air conditioning unit. Found the system running but not providing adequate cooling. Inspected electrical components, refrigerant levels, and airflow. Discovered the outdoor condenser coil was significantly dirty, restricting heat exchange and causing poor system performance.
Shut off power to the unit and performed a thorough cleaning of the condenser coil using coil cleaner and water. Removed all debris and buildup from the fins to restore proper airflow. After cleaning, rechecked system operation. Verified compressor and condenser fan motor were operating within normal parameters. Monitored refrigerant pressures, which stabilized after cleaning, indicating improved efficiency.
System restored to normal operation. Verified cooling at the supply vents. Advised the customer on routine maintenance and the importance of keeping the condenser coil clean to prevent future performance issues.
Outcome: No cooling issue resolved. Condenser coil cleaned. System operating properly at this time.
-
Capacitor replacement Garland,TxCapacitor replacement Garland,Tx
Upon arrival for a no cooling call, the system was found non-operational. Inspection revealed the outdoor fan and compressor were not running. Diagnosed a failed dual run capacitor as the root cause. Replaced the faulty capacitor, restored power, and confirmed proper system operation. Cooling function resumed.
-
Mini-Split Condenser repair Dallas,TxMini-Split Condenser repair Dallas,Tx
Responded to a no cooling call. Checked out this mini-Split condenser unit. After diagnosis, found the coil dirty and unit low on Freon. We washed the condenser coil, repaired the Ac leak and topped off charge.
-
Air conditioning repair Dallas,TxAir conditioning repair Dallas,Tx
Responded to a no cooling call in call in Dallas,Tx Saturday night. We found the evaporator coils are coil frozen back to the condenser. We had to run the blower to thaw out the unit. After the unit was thawed we checked everything out on this 1983 air conditioner. The system was 3 pounds low. Performed a leak search and found the hi/low schrader valves extremely loose. After replacing valves. We re charged the system, rather than trying to upsell a new system. Although it was recommended at the time.
-
Annual Maintenance Ac Tune-Up Plano,TxAnnual Maintenance Ac Tune-Up Plano,Tx
Our annual spring AC tune-up is a comprehensive maintenance service designed to prepare your air conditioning system for the warmer months ahead. Our expert technicians will thoroughly inspect, clean, and optimize your AC unit to ensure it runs efficiently and effectively throughout the summer. The process includes checking refrigerant levels, cleaning coils, inspecting ductwork, tightening electrical connections, replacing air filters, and testing the thermostat. By catching potential issues early, we help extend the lifespan of your unit, improve energy efficiency, and reduce the risk of unexpected breakdowns. A spring tune-up is an essential step in keeping your home cool and comfortable all season long while avoiding costly repairs.
-
Annual AC Maintenance in Plano,TxAnnual AC Maintenance in Plano,Tx
Our annual spring AC tune-up is a comprehensive maintenance service designed to prepare your air conditioning system for the warmer months ahead. Our expert technicians will thoroughly inspect, clean, and optimize your AC unit to ensure it runs efficiently and effectively throughout the summer. The process includes checking refrigerant levels, cleaning coils, inspecting ductwork, tightening electrical connections, replacing air filters, and testing the thermostat. By catching potential issues early, we help extend the lifespan of your unit, improve energy efficiency, and reduce the risk of unexpected breakdowns. A spring tune-up is an essential step in keeping your home cool and comfortable all season long while avoiding costly repairs.
-
Air conditioning Repair. Royse City, TxAir conditioning Repair. Royse City, Tx
Responded to a no cooling call in Royse City. Upon diagnosis, found compressor contactor burnt and pitted. Replaced the contactor and restored unit.
After picture of replacing compressor contactor.
-
Air conditioning Repair in Royse City,TxAir conditioning Repair in Royse City,Tx
Responded to a no cooling call in Royse City. Upon diagnosis, found compressor contactor burnt and pitted. Replaced the contactor and restored unit.
-
Air conditioning repair in crandall,TxAir conditioning repair in crandall,Tx
No cooling call in Crandall,Tx
Upon arrival, we diagnosed the issue with the whole-home ventilation system, which was running continuously and pulling in outside air. This caused an increase in humidity inside the home. To resolve this, we shut off the control to stop outside air from entering the home, as this was contributing to the high humidity levels. Additionally, allowing outside air to enter could lead to the air filter getting dirty more quickly. The system has been adjusted to prevent further outside air intake, and the humidity levels should stabilize.
-
Replaced evaporator coil in heath,TxReplaced evaporator coil in heath,Tx
In Heath, TX, we recently replaced an evaporator coil as part of an HVAC system upgrade. The original evaporator coil had become inefficient, leading to poor cooling performance and increased energy consumption. Our team first performed a comprehensive diagnostic inspection of the system to ensure that the issue was indeed with the evaporator coil. We then proceeded to shut down the air conditioning system and carefully remove the old coil. Afterward, we installed a high-efficiency replacement coil that was compatible with the existing HVAC unit, ensuring proper airflow and refrigerant circulation.
To prevent future issues, we ensured that all connections were sealed and tightened, and the refrigerant levels were properly adjusted. After installation, the system was thoroughly tested for optimal performance, ensuring that the airflow and cooling capacity were restored to industry standards. By replacing the evaporator coil, we significantly improved the overall efficiency of the HVAC system, providing our customer in Heath, TX, with reliable, energy-efficient cooling throughout the year.
-
Replaced evaporator coil in Heath,TxReplaced evaporator coil in Heath,Tx
In Heath, TX, we recently replaced an evaporator coil as part of an HVAC system upgrade. The original evaporator coil had become inefficient, leading to poor cooling performance and increased energy consumption. Our team first performed a comprehensive diagnostic inspection of the system to ensure that the issue was indeed with the evaporator coil. We then proceeded to shut down the air conditioning system and carefully remove the old coil. Afterward, we installed a high-efficiency replacement coil that was compatible with the existing HVAC unit, ensuring proper airflow and refrigerant circulation.
To prevent future issues, we ensured that all connections were sealed and tightened, and the refrigerant levels were properly adjusted. After installation, the system was thoroughly tested for optimal performance, ensuring that the airflow and cooling capacity were restored to industry standards. By replacing the evaporator coil, we significantly improved the overall efficiency of the HVAC system, providing our customer in Heath, TX, with reliable, energy-efficient cooling throughout the year.
-
Air conditioning Repair. Crandall,TxAir conditioning Repair. Crandall,Tx
Responded to a no cooling call in Crandall,Tx. Customer experienced the condenser motor not spinning. After diagnostics, found the dual capacitor for the compressor and fan weak. Replaced the dual capacitor and started unit and checked operation. System is now running properly .
-
Air conditioning Repair. Frisco TxAir conditioning Repair. Frisco Tx
We responded to a no cooling call in Frisco and discovered a blown dual capacitor. After replacing the capacitor, the unit is now functioning properly.
-
Air conditioning Tune up- cedar hill,TxAir conditioning Tune up- cedar hill,Tx
We recently completed an air conditioner tune-up in Cedar Hill, TX, ensuring the system was running at peak efficiency. Our technicians performed a thorough inspection, cleaned key components, checked refrigerant levels, and ensured all electrical parts were functioning properly. This preventative maintenance helps extend the lifespan of the unit and ensures homeowners stay cool during the hot Texas summer.
-
Ac Repair- Dallas,TxAc Repair- Dallas,Tx
In Dallas, TX, a Goodman condenser unit had a no cooling issue. The technician discovered that the condenser fan motor had failed. After replacing the motor and ensuring proper installation, the unit was tested and began cooling effectively, resolving the issue.
-
Compressor Contactor Replaced Dallas,TxCompressor Contactor Replaced Dallas,Tx
During the service call, it was determined that the contactor was malfunctioning, preventing the system from properly engaging and causing cooling issues. The faulty contactor was replaced with a new one, restoring proper functionality to the system and ensuring it operates as expected.
-
Air conditioning repair Dallas TxAir conditioning repair Dallas Tx
During the service call for a cooling issue, it was discovered that the air filter was severely clogged, significantly restricting airflow. This restriction was preventing the system from operating properly, causing the cooling problem. The filter was replaced on-site for the homeowner, restoring optimal airflow and ensuring the system could function as intended, resolving the issue.
Let me know if you need any adjustments!
-
Air conditioning Repair. Dallas,TxAir conditioning Repair. Dallas,Tx
The unit was not cooling properly, and upon inspection, we found the condenser coil was clogged with leaves at the bottom of the unit. We removed the top of the unit, cleared out the debris, and thoroughly washed the condenser coil to restore optimal performance.
-
Air conditioning Repair. Dallas,TxAir conditioning Repair. Dallas,Tx
The unit was not cooling properly, and upon inspection, we found the condenser coil was clogged with leaves at the bottom of the unit. We removed the top of the unit, cleared out the debris, and thoroughly washed the condenser coil to restore optimal performance.
-
New condenser motor. Dallas,TxNew condenser motor. Dallas,Tx
After picture-Replaced the condenser motor on the Carrier unit with a genuine OEM motor. Ensured proper installation and confirmed that the unit is now operating smoothly and efficiently with the new motor. All work was completed using OEM parts to maintain optimal performance and warranty compliance. The system is fully functional and ready for continued operation.
-
Condenser Motor Replacement. Dallas,TxCondenser Motor Replacement. Dallas,Tx
Before picture of the condenser motor replacement on the Carrier unit with a genuine OEM motor. Ensured proper installation and confirmed that the unit is now operating smoothly and efficiently with the new motor. All work was completed using OEM parts to maintain optimal performance and warranty compliance. The system is fully functional and ready for continued operation.
-
Air Conditioning Repair. Dallas TxAir Conditioning Repair. Dallas Tx
Upon receiving the “no cooling” call, our technician promptly arrived at the site and began a thorough inspection of the system. After assessing the unit, it was determined that the condenser coil was severely plugged with dirt and debris, restricting airflow and preventing the system from effectively releasing heat. To address the issue, we powered off the unit for safety and carefully cleaned the condenser coil, removing the blockage and ensuring proper airflow. Once the coil was cleared, the technician conducted a performance check to ensure the system was running smoothly and cooling properly. After confirming the issue was resolved, we advised the customer on regular maintenance practices to prevent future blockages. The unit was restored to full functionality, and the cooling system was back in operation.
-
Air conditioning Repair Plano,TxAir conditioning Repair Plano,Tx
The air conditioning repair for the Lennox unit involved a thorough diagnosis after the thermostat was found to have no power. Upon inspection, it was determined that the issue stemmed from the furnace switch being turned off. Once the switch was turned back on, the thermostat regained power, and the system was fully operational again. This was a simple yet effective repair, ensuring the air conditioning unit was restored to proper working condition.
-
Heating repair. Irving,TxHeating repair. Irving,Tx
A no-heat service call was received in Irving, TX. Upon diagnosing the system, it was determined that the ignitor was faulty, and the flame sensor was dirty. We proceeded with replacing the ignitor and thoroughly cleaning the flame sensor to restore proper functionality. After completing the repairs, we started the unit, monitored its operation, and confirmed that it was working efficiently, providing heat as expected. The system is now fully operational.